eVITA 12/ eVITA 15 Patient Monitor

Sub-intensive care/bedside care
(12 inch) (15 inch)

HD Display,Touch Screen,Intelligent Setting,More Readable

OVER VIEW

The eVITA 12/15 series patient monitor are designed to meet the daily clinical needs about the
Sub-intensive patient monitoring

eVITA12 12 inch
eVITA15 15 inch

Features

Excellent Performanc:

  • LowPulseStr TM SPO2 algorithm more reliable readings of SPO2 during low perfusion and motion.
  • iFastBPTM NIBP algorithm used for fast and comfortable measurement.
  • wSmartHeart
    TM ECG technology for more safey monitoring of patient.
  • iRealRespTM Breating rate technology to get the real reading during
    motion.
  • wSmartGasTM Capnograph technology to get reliable reading during
    multi-environment.

Powerful function

  • Multi display mode other beds view/Big font.
  • Wifi connectivity more flexible application.
  • 12 or 15 inch screen can be optional.
  • Easy to use with excellent usability.
  • eTeleViewTM Central Montior system support.
  • Smart touch screen for easy operation.

Multi-scenario application: Sub-intensive care/bedside care

Central Monitoring System

Central Monitoring System supports
up to 64 beds or 64 patients across clinical units at the same time.
72 hours of 64-channel holographic physiological waveform storage and review.
Provides review of up to 240 hours trend data storage, 720 alarm events per beds.
Bi-directional communication with eVITA 12/15 Series monitors for enhanced patient care.

Product Specifications

GENERAL

 

Dimensions :                           12inch(31cm*14cm*24cm)

                          15inch(39cm*15cm*26cm)

…………………………………………………………………………………………

Weight : 4.5kg

…………………………………………………………………………………………

Screen size:12 inch and 15 inch

 

PARAMETER

SPO2

…………………………………………………………………………………….

SPO2 Range: 0~100%

SPO2 Accuracy :  70~100%,±2%   <70%,Undefined

PI Range : 0~20%

PVI Range : 0.001%

PR Range : 25-250bpm

PR Accuracy : ±2bpm or ±2%(whichone is greater)

ECG

…………………………………………………………………………………………………….

ECG Range :  0.15~5.5mV

ECG Resolution : 2.36uV/LSB

HR Range : 15~300bpm(adult) 15~350bpm(child/neonate) HR Accuracy  :  ±1bpm or ±1% (whichone is greater)

RR Range : 0~120bpm

RR Accuracy : 15~120rpm : ±2rpm or ±2%  <15rpm:Undefined

TEMP

……………………………………………………………………………………………………………………………………………………………………………………………………

Range                             0-50°C Accuracy                        ±0.1°C

Resolution                     0.1°C

NIBP

……………………………………………………………………………………………………………………………………………………………………………………………………

Pressure  Range           0~300mmHg

Pressure  Accuracy      ±2mmHg or  ±1% of reading (take the larger value)

Resolution                      1mmHg

SYS Range                       Adult:40-270mmHg       Pediatric:40-200mmHg      Neonate:40-130mmHg

DIA Range                       Adult:10-210mmHg       Pediatric:10-162mmHg        Neonate:10-90mmHg

Mean Range                   Adult:20-230mmHg       Pediatric:20-170mmHg       Neonate:20-100mmHg

Accuracy                          The mean deviation<±5mmHg         The standard deviation<8mmHg

RESP

……………………………………………………………………………………………………………………………………………………………………………………………………

Range                             0-120Rpm

Accuracy                       15-120Rpm           ±2Rpm or ±2% of the reading (which one is larger)         Others,undefined Resolution                      1Rpm

IBP(Optional)

……………………………………………………………………………………………………………………………………………………………………………………………………

Pressure  Range           -50~350mmHg

Accuracy                        ±3mmHg or  ±1% of reading

PR  Range                      25-250bpm

PR  Accuracy                 ±2bpm or ±2% (whichone is greater)

EtCO2 (Optional)

……………………………………………………………………………………………………………………………………………………………………………………………………

CO2  Range                   0~20.0vol%

CO2  Accuracy              0~12vol%:±(0.2vol%+2%of reading)       12~20vol%:±(0.2vol%+6%of reading) AwRR  Range                0~150rpm

AwRR  Accuracy           mainstream:0~150rpm,±1rpm        Sidestream:0~69rpm,±1rpm        70~150rpm,Undefined

Patent

SPO2

…………………………………………………………………………………………………

Patent              Patent No: ZL 2019 1 0907433.8

                     ZL 2019 2 1510989.5

                     ZL 2019 2 1596814.0

RESP

………………………………………………………………………………………………

Patent   Patent No: ZL 2014 1 0429201.3

                     ZL 2014 2 0489133.5

                     ZL 2021 2 0480587.6

EtCO2

………………………………………………………………………………………………

Patent              Patent No: ZL 2018 1 0713045.1

                     ZL 2018 1 0713152.4

                     ZL 2020 2 1177039.8

                     ZL 2019 2 0722093.7

                     ZL 2017 2 0804416.8

                     ZL 2017 2 0293754.X

ECG

………………………………………………………………………………………………

Patent   Patent No: ZL 2015 0484280.2

                     ZL 2019 1 0064711.8

                     ZL 2017 1 0691935.2

                     ZL 2021 2 0480587.6

Scroll to Top